ADMIRAL – Status display

Emitter – All models

1 Yellow LED2 Red LED3 Green LEDDisplayMeaning
8System power-on – Initial TEST
L / HTEST condition
LGUARD condition. Low range
HGUARD condition. High range
CodeFAIL condition – The type of fault is identified by the code number on display. See next „Fail condition tablel“

Fail condition

Display codeMeaning
F – PRange selection incorrect or modified
F – AInternal error (add-on board)
F – 3Internal error (master board)
F – 4Internal error

 

Receiver – ADMIRAL AD

1 Yellow LED2 Red LED3 Green LEDDisplayMeaning
8System power-on – Initial TEST

BREAK condition
Received beam signal intensity is weak
GUARD condition
CodeFAIL condition – The type of fault is identified by the code number on display. See next „Fail condition table“

Fail condition

Display codeMeaning
OOvercurrent on one or both outputs (OSSD)
F – 1Detection of a hazardous interfering Emitter condition. The Receiver is able to receive the beams emitted by two different Emitters at the same time.
(This fault is displayed for at least 30 seconds)
F – 2Connection of load between static outputs (OSSD) and the positive power supply line (+ 24 Vdc)
F – 4Internal failure relating to the microcontroller boards
F – 5Erroneous connection of static outputs (OSSD)
F – 6Probable short circuit between the two outputs (OSSD)

 

Receiver – ADMIRAL AX

1 Yellow LED2 Red LED3 Green LEDDisplayMeaning
8System power-on – Initial TEST
CC displayed for 10 sec. – Manual restart with feedback disabled
CC displayed for 10 sec. – Manual restart with feedback enabled
CC displayed for 10 sec. – Automatic restart with feedback disabled
CC displayed for 10 sec. – Automatic restart with feedback enabled

BREAK condition

D

BREAK condition with weak signal

CLEAR condition. Waiting for restart

D

CLEAR condition with weak signal
Blinking

Master in CLEAR, Slave in BREAK conditions (Master Models only)
Blinking 

D

Master in CLEAR, Slave in BREAK conditions with weak signal.(Master Models only)
GUARD condition
DGUARD condition with weak signal
 Receiver initialization
CodeFAIL condition – The type of fault is identified by the code number on display. See next „Fail condition table“

 

Fail condition

Display codeMeaning
OOverload of the OSSD static outputs
F – CCustomer configuration rejected
F – 2OSSD erroneously connectedt o 24VDC
F – EExternal Feedback contactors missed
F – 3Internal error
F – 4
F – A
F – 6OSSD1 OSSD2 shortcircuit
F – 0Overload of the OSSD static outputs (only for MASTER models)
F – 5OSSD static outputs error
F – IInterfering dangerous Emitter detected.
The receiver is able to receive simultaneously the beams from two
different Emitters
(30 sec)
F – USLAVE connections incorrect (only for MASTER models)
F – HUser configuration changed without system restart (only for MASTER models)

 

Receiver – ADMIRAL AX BK

1 Yellow LED2 Red LED3 Green LEDDisplayMeaning
8System power-on – Initial TEST
CC displayed for 10 sec. – Blanking S.O.P.O. (Without Object Presence Obligation) Mode A1
CC displayed for 10 sec. – Blanking S.O.P.O. (Without Object Presence Obligation) Mode A2
BlinkingCC displayed for 10 sec. – Blanking S.O.P.O. (Without Object Presence Obligation) Mode A3
CC displayed for 10 sec. – Blanking C.O.P.O. (With Object Presence Obligation) Mode B1
CC displayed for 10 sec. – Blanking C.O.P.O. (With Object Presence Obligation) Mode B2

BREAK condition

D

BREAK condition with weak signal
   

B

BREAK condition in case of Mode B1/B2 blanking
  

B

BREAK condition in case of Mode B1/B2 blanking with weak signal

J

Master in CLEAR, Slave in BREAK conditions (Master Models only)

J

Master in CLEAR, Slave in BREAK conditions with weak signal.(Master Models only)
GUARD condition
GUARD condition with weak signal
RActive blanking conditions
RActive blanking conditions with weak signal
 Receiver initialization
CodeFAIL condition – The type of fault is identified by the code number on display. See previous „Fail condition table“